
Add to Cart
China cheap price vet infusion pump single channel syringe pump for Vet VP04
Item | Technical Parameter |
Injection Mode | Constant Rate, Time mode, Drug Weight, Micro, Sequential, Drug Library Mode |
Syringe Size | 5ml, 10ml, 20ml, 30ml, 50/60ml, auto recognition |
Flow Rate Range | 5ml: 0.10ml/h-60.00ml/h 10ml: 0.10ml/h-300.00ml/h 20ml: 0.10ml/h-400.00ml/h 30ml: 0.10ml/h-600.00ml/h 50/60ml: 0.10ml/h-1200.00ml/h |
Flow Rate Increment | 0.01ml/h |
Preset Time | 1s-99hr59min59s |
Parameter Changed During Injection | Support change of VTBI, flow rate during injection |
Accuracy | ≤±2%(±1% mechanical accuracy included) |
Preset Volume(VTBI) | 0.1~9999.99ml & empty |
Accumulated Volume | 0.00~999.99ml |
Purge Rate | 5ml: 30-60ml 10ml: 150-300ml 20ml: 200-400ml 30ml: 300-600ml 50/60ml: 600-1200ml |
Bolus Rate | 5ml: 0.10ml/h-60.00ml/h 10ml: 0.10ml/h-300.00ml/h 20ml: 0.10ml/h-400.00ml/h 30ml: 0.10ml/h-600.00ml/h 50/60ml: 0.10ml/h-1200.00ml/h |
KVO | 0.10-5.0ml/h adjustable |
Occlusion Pressure | 8 level adjustable, 20Kpa-140Kpa, dynamically pressure value display. |
Alarm | Finished, near finished, near empty, empty, occlusion, syringe disconnected, no operation, parameter error, syringe size error,low battery, battery lost, battery ran out, AC power lost, abnormal injection, communication error. |
Syringe Management | Preset 20 syringe brands, can add or edit the brand, accept all brands after calibration. |
Display | 3.5' TFT color LCD, 10 level brightness adjustable. |
Power Supply | AC power, AC:100V~240V, 50Hz/60Hz,≤25VA |
Communication Port | USB, RJ45 for future use, Ethernet Port |
Syringe Size | 5ml, 10ml, 20ml, 30ml, 50/60ml, auto recogintion |
Battery | Rechargeable Lithium battery, DC11.1V, 3000mAh, operating time: ≥9h@5ml/h |
Alarm Voice | Standard Medical Alarm Voice with Mute function, 8 levels adjustable. |
Event log | 1000 event log, can be transmitted to PC with USB |
Software Upgrade | Upgrade the software with USB |
Operation Environment | Temperature: +5℃~+40℃, Relative humidity:20%~90%, Atmospheric pressure: 70~106Kpa |
Classification | Class II, Type CF, IPX4 |
Dimension | Size: 275mm*145mm*160mm, Weight: 2.1KG |
Other Function | Double CPU, Password function, Multi Language, Pressure Release function, 90° rotatable IV pole, 4 soft function key, key lock function, numeric keypad, Pause function etc. |
Application | Intravenous injection |
Safe and reliable
1.1 Using double CPU design, reliable data transmission, safer syringe.
1.2 High precision occlusion pressure sensors design, 8 levels adjustable of sensitivity occlusion pressure.
1.3 Real-time self-testing,real-time self-testing when startup and during syringe process, ensure the safety of each component
and each function, safer syringe.
1.4 Automatic switching between AC and DC power supply , battery backup time more than 9hours under double channel are using,
ensure no interruption when no AC power supply or in moving condition.
1.5 Alarm prompt with sound, light and message, 8 adjustable level of alarm volume.
1.6 Dynamic pressure value display,and real-time detect occlusion pressure status.
1.7 Various alarm, avoid the suddenly accidents during infusion process.
1.8 Motor anti-reverse function, avoid preventing upstream absolutely.
1.9 10000 event log, which reduce doctor-patient disputes and promote harmony between doctors and patients.